HTM1600 Motor

RATINGS:

  • Maximum Continuous Power: 1600HP (1193 KW), 9338 lb-ft., 1430 Amps, 600 – 690 VAC, 900 RPM, Constant Output Speed: 1000 – 1800 RPM
  • Intermittent Duty Cycle: 2250HP (1678 KW), 13,131 lb-ft., 2025 Amps, 600 – 690 VAC, 900 RPM
  • Duty Cycle: 60 sec. ON, 120 sec. OFF Constant Output Speed: 800 – 1400 RPM
  • Max RPM: 3000
  • Ambient Temp.: -40° to +55

Features & Specifications

HTM1600 Features
Form Wound - (VPI)
Copper Alloy Rotor Bars and End Ring
Class H Insulation
(VFD) Inverter Duty
4532 Forged High-Strength Shaft
Single Shaft with Oilfield Hub
OPE Insulated Bearing
IP44 Enclosure
Pressurized connection box (IP54) mounted on right or left side of motor as viewed from non-drive end, with bolt on cable connections and terminations for pressure sensor, thermostat, space heater, lockout switch & blower unit.
Blower Assembly; 20HP, Explosion Proof, 3 Phase, 60 Hz, 460 Volts
(6) 100 Ohm Platinum RTD's (2) per phase
Pressure sensor, Explosion Proof
Lockout Switch, Explosion Proof
Space Heater, 120/240 Volt, Explosion Proof
Stub Shaft / Encoder Mount optional
Approx. Weight: 7,560 Lbs

Engineering Data

  • Service Speed:
    • Belt drive: 0˜2300 RPM (2300˜3000 RPM: short time drive).
    • Direct Coupled: 0˜3000 RPM (Continuous).
  • Dielectric Test: 4025 V (900*2.25+2000, 900 V is inverter input Voltage).
  • Permissible Vibration +/- 5 m/S² (+/-7.5G).
  • Noise (@ No-Load): 91 dB(A) at 1m from motor frame.
Output (HP) Continuous1600
Output (HP) Intermittent2250
Output (KW) Continuous1193
Output (KW) Intermittent1678
Voltage (V) Continuous600
Voltage (V) Intermittent600
Current (A) Continuous1430
Current (A) Intermittent2025
Speed (1/min) Continuous900
Speed (1/min) Intermittent900
Frequency (HZ) Continuous45.6
Frequency (HZ) Intermittent46.2
Efficiency (%) Continuous94.0
Efficiency (%) Intermittent93.7
Power Factor (%) Continuous87.1
Power Factor (%) Intermittent85.1
Slip (%) Continuous1.2
Slip (%) Intermittent2.08